Ceco medallion and trio series steel stiffened doors offer a range of products suited for institutional and commercial security uses.
1 hour fire rated door frame detail.
Doors with glass lights or doors equipped with fire exit devices may not have louvers.
Please contact technical glass regarding your individual hardware requirements.
These requirements apply to all fire rated doors frames and windows.
The door must be self closing and positive latching push pull plates cannot be used on a fire rated door and ul approved hinges must be used.
6 fire door frames fire doors frames are not affected by the exposure ratings and opening classifications that apply to doors.
Frames used in masonry walls may be used with a maximum 3 hour fire door while frames used in drywall stud walls are intended to be used with a maximum 1 1 2 hour fire door.
3 hour 1 1 2 hour.
Ferche millwork is the industry s leading manufacturer of hardwood mouldings and veneered millwork.
Consult with individual fire door frame manufacturers listings for fire door frames that can be used in drywall stud walls with a maximum 3 hour.
All door hardware for fireframes designer series doors or fireframes heat barrier series doors integrated into fireframes aluminum series frames is supplied by technical glass products.
If a frame bears a recognized label qualifying it as a fire door frame it may support a 3 hour a 1 1 2 hour a 3 4 hour or a 1 3 hour door.
8 0 x 9 0.
3 hour 1 1 2 hour.
The following technical data sheets show the various frame types available to suit pyropanel fire doors including steel frames 1 and 2hr timber frames mdf frames and also the methods that are approved to fix frames to various wall types.
Fire window frame knock down construction drywall walls only 1 1 2 hour rated 18 gauge frames single swing frame 1 1 2 hour rated fire labeled doors available.
Fire ratings are available from 20 minutes through 3 hours with 450 degree f temperature rise option.
Don t settle for hollow metal specify ferche fire rated wood door frames today.
Fire door frames frames used in masonry walls may be used with a maximum 3 hour fire door while frames used in drywall stud walls are intended to be used with a maximum 1 1 2 hour fire door.
Fire rated door and frame.
Per section detail 1 1 2 drywall pressure anchor frames maximum jamb opening size.
Face sheets are available in gauges 18 to 14 with door thicknesses of both 1 3 4 and 2.
The wall door frame door and hardware must all be fire rated.