For this reason a fire rated drywall is sometimes called one hour fire wallboard.
1 hour fire rated wall construction.
Thick shall be attached to furring channels as described in item 6.
1 hour fire rated construction non loadbearing acoustical performance reference construction detail description test number stc test number index wt.
7 alternate based on 2 1 2 gauge steel studs and 1 2 face layer laminated ga wp 105153ngc 2318 based on 2 glass fiber.
The fire resistant rating also requires the rating exposure to be for both sides.
According to the book commercial drafting and detailing a typical one hour fire rated wall consists of 2x4 studs spaced 16 inches from the center of one stud to the center of the next covered by 5 8 inch type x gypsum board.
These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies.
When item 7b steel framing members is used nonbearing wall rating is limited to 1 hr.
Use special fiberglass rated for use in firewalls.
Where to install type x drywall.
If a conventional 1 2 inch thick sheet of drywall will stand up to 30 minutes of fire then the added 1 8 inch found in the type x drywall along with its other properties will double your margin of safety to 60 minutes.
Use steel studs and two layers of 1 2 inch type c drywall on each side of the studs for a two hour fire rating on an interior wall.
When specified for these 1 hour fire rated assemblies lp flameblock sheathing reduces dead load and wall thickness versus common alternatives.
To the centerline of a street an alley or public way.
Thickness of insulation item 4 is 3 in and two layers of gypsum board panels 1 2 in.
Mount a 1 1 2 inch fiberglass barrier inside the studs.
Building code requirements.
It also providesbetter substrate for securely fastening exterior facing materials.
Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.
To an imaginary line between two buildings on the lot.
Walls less than 5 feet from the property lot line must be of a listed hour fire1 resistant construction.
Fire rated wood frame wall and floor ceiling assemblies.
To the closest interior lot line.
For occupancies such as stores apartments of fices and other commercial and industrial uses build ing codes commonly require floor ceiling and wall assemblies to be fire resistance rated in accordance with standard fire tests.
Type x gypsum board is wallboard to which non combustible fibers have been added.