Type c fire rated drywall sometimes referred to as improved.
2 hour fire rated drywall.
Why fireproof drywall is fire rated.
6 usg fire resistant assemblies test certiļ¬cation test conditions and fire and sound tested assemblies listed in this selector are based on characteristics properties and performance certificationof materials and systems obtained under controlled test conditions as set forth in the appropriate astm standard in effect at the time of test.
These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies.
Gypsum panel end joints located midway between continuous channels and attached to additional pieces of channels 54 1372 mm long with screws 12 305 mm o c.
Mount a 1 1 2 inch fiberglass barrier inside the studs.
The 2 hour area separation wall system is a 2 hour fire wall consisting of 2 in.
With 1 25 mm type s drywall screws 12 305 mm o c.
Have a look at this example of a fire rated certificate.
Get free shipping on qualified fire resistant drywall sheets or buy online pick up in store today in the building materials department.
This certifies that the drywall system is fire rated.
As added benefits type x absorbs sound slightly better and is slightly stronger than conventional 3 8 inch or 1 2 inch drywall.
Use special fiberglass rated for use in firewalls.
Most type x drywall has a one hour fire rating.
1 hour and 2 hour fire rated drywall.
Simply it is drywall that will stand up against flame longer than regular drywall.
Type x fire rated gypsum drywall that is 5 8 inch 15 9mm thick and installed on each side of nominal 2 inch x 4 inch 38x89mm wood studs spaced 16 inch 400mm o c.
One hour fire rated.
Or 3 5 8 inch 610 mm steel studs spaced 24 o c.
Has a minimum fire rating for the assembly of 1 hour which is a typical requirement for many building codes.
These listings are short summaries to serve as a.
There are many ways to meet the requirements for 2 hour fire rated separation walls including foundation to roof masonry walls separating the units.
50 8 mm light gauge steel h studs that secure two layers of 1 in.
25 4 mm shaftliner panels friction fit between studs and a minimum 3 4 in.
An increasingly common and popular method is the gypsum area separation wall which consists of individual stud framed walls filled with fiberglass insulation for each housing unit which are separated by a special construction that consists of.
Type x is by no means 100 percent fireproof.
Every fire rated installation comes with the appropriate documentation from the supplier.
Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.
19 1 mm air space on each side.